Fiber mist eliminators in chlor-alkali: three positions, one material trap
11/27/2026- A CFD cut through one vane channel validates turning, pressure drop and where the liquid is meant to settle. It says nothing about capture efficiency and nothing about distribution across the pack.
- In the field shown here the inlet is 5 m/s in the channel, which at an open fraction near 0.61 is about 3.1 m/s face velocity — roughly 70% of the 4.39 m/s limit for a vertical vane pack with K = 0.152.
- Pressure drop follows the dynamic head, not the flow: at 5 m/s in air at 1.2 kg/m³ the head is 15 Pa, so a total loss coefficient of 4 to 6 gives 60 to 90 Pa per element, before entrance, exit and liquid load.
- The useful output of the run is not the pretty contour. It is the pair of numbers behind it: the mesh-independence check and the measured DP the model is compared against.
What the two pockets are for
A double-pocket vane is a channel with two bends and two dead-end pockets. The bends do the turning: the gas is forced through a change of direction, and a droplet with enough inertia keeps going straight long enough to reach the wall. The pockets do the draining: they give the liquid a place to leave the gas stream, slow down, and run down a surface that is not being scrubbed by the main flow.
That is the whole design intent, and it is also why a double-pocket vane is harder to get right than a single zig-zag. Every pocket is a compromise between two requirements that pull in opposite directions:
- Deep enough to be quiescent. The pocket has to be slow enough that the film on its wall is not re-entrained by the passing gas.
- Shallow enough not to waste the section. Every millimetre of pocket is section that is not turning gas, so a generous pocket costs capacity at the same face area.
The CFD exists to show which side of that compromise the geometry actually landed on. Not to show that the vane “works” — a contour plot will always look like it works.
Reading the velocity field

Four things are worth reading off this field before any number is quoted from it.
1. The core is faster than the inlet. After each bend the flow attaches to the outer wall and runs at 5 to 8 m/s, against a 5 m/s inlet. That is normal and it is the point of a vane: the gas is accelerated around the bend, and the droplets that cannot follow the streamline are thrown at the wall where the velocity is highest. It also means the wall is the place where re-entrainment starts if the film gets too thick.
2. The pocket is genuinely slow. Inside each pocket the field drops to roughly 1 to 2 m/s, and lower still at the floor. That is the number that matters for drainage: if the pocket is at 4 m/s it is not a pocket, it is part of the channel, and the liquid it was supposed to collect is carried straight through to the next bend.
3. There is a separation wedge at the inner nose. Directly downstream of each inner tip there is a low-velocity wedge — the blue region in the picture — where the flow has left the surface. That wedge is dead section: no turning, no capture, and a place where liquid can be held and later shed as a slug.
4. The two halves are not symmetric. The channel is fed from the bottom and the pattern repeats, but the first bend does not see the same inlet condition as the third. A model that looks acceptable over three passes can still show the last pass running 15 to 20% faster than the first, which is the signature of a channel that is too short for its own pressure recovery.
Pressure drop from the same field
The pressure field is solved at the same time as the velocity field, so the DP is the cheapest reliable output of the run. It is read as a loss coefficient against the dynamic head:
ΔP = ζ · ½ ρ u²
At 5 m/s in air at 1.2 kg/m³ the dynamic head is 15 Pa. Measured vane geometries land at a total ζ of about 4 to 6 for two to three passes, which puts the clean element at 60 to 90 Pa:
| Channel velocity | Dynamic head, air at 1.2 kg/m³ | DP at ζ = 5 | Face velocity at 0.61 open fraction |
|---|---|---|---|
| 3 m/s | 5.4 Pa | 27 Pa | 1.8 m/s |
| 4 m/s | 9.6 Pa | 48 Pa | 2.4 m/s |
| 5 m/s | 15 Pa | 75 Pa | 3.1 m/s |
| 6 m/s | 21.6 Pa | 108 Pa | 3.7 m/s |
Two corrections have to be applied before this number is compared with a plant reading. The first is density: the same channel velocity in a gas at 20 kg/m³ produces a DP sixteen times higher, which is why high-pressure vane packs are quoted in kPa and atmospheric ones in Pa. The second is liquid load: a dry-element DP is the commissioning number, and a vane carrying liquid sits above it. Installed packs are usually quoted at 0.1 to 0.5 kPa, or 0.05 to 0.15 kPa where the service is low-pressure and clean; the gap between the two bands is density, liquid load and fouling, not a different geometry.
The reason to compute DP rather than measure it on the drawing is that DP is the one output a customer can check in the field with a manometer, and therefore the one output that has to be right.
How to set up a vane CFD that can be defended
Most vane CFD in a sales folder is a contour plot with no setup behind it. A run that can survive a technical review has five properties, and none of them are expensive:
- A stated turbulence model and wall treatment. Steady RANS with k-ω SST is the usual choice for separating flow in a bent channel; the near-wall treatment has to match the mesh, either y+ below about 1 with resolution or a consistent wall function. A model that switches treatment between runs is not comparable to itself.
- Mesh independence, reported. Three levels, with the DP changing by less than 2% between the middle and fine mesh. Quoting a fine mesh without the coarse comparison proves nothing.
- Documented boundary conditions. Uniform inlet velocity, turbulence intensity and hydraulic diameter, outlet at gauge zero, and wall roughness either measured or declared smooth. A vane CFD with a guessed inlet profile is a CFD of the guess.
- A sensitivity run on the inlet. The same geometry with a 10 to 15% skewed inlet profile. If the DP moves by more than a few per cent, the geometry is sensitive to upstream distribution and the pack needs a straightener.
- A comparison against something measured. Test-rig DP on a single channel, or plant DP on a comparable pack. Without this the run is a hypothesis.
Everything else — the colour map, the streamlines, the animation — is presentation. Presentation is fine; it just is not evidence.
What CFD cannot prove
This is the part of the conversation that separates a design tool from a marketing picture. A steady RANS solution of dry gas through one channel cannot tell you:
- Capture efficiency. That requires a droplet phase: Lagrangian tracking with a defined size distribution, a drag law valid in the Stokes-to-intermediate range, and a decision about what happens on impact — stick, bounce, or film. Change the bounce rule and the efficiency moves by tens of per cent. The defensible number comes from a rig, and CFD only explains why the rig behaves as it does.
- Distribution across the pack. One channel is not a pack. The pack sees a vessel’s velocity profile, the wall boundary layer, the inlet jet, and the blockage of its own frame. Vessel-level maldistribution is a full-geometry problem, and it is usually the reason a pack that tested well in a duct underperforms in a tower.
- Liquid behaviour. Film thickness, flooding and re-entrainment are multiphase problems with surface tension. A single-phase field tells you where the liquid should go, not where it does go.
- Fouling. Nothing in a clean-gas run predicts the salt or solids that close a channel in eighteen months.
None of this makes CFD optional. It makes it a tool with a boundary, and the boundary is exactly the line between “the geometry turns the gas correctly” and “the device removes the droplets it was bought to remove”.
Three things the field usually exposes
When a double-pocket geometry is modelled honestly, the problems that turn up are predictable and all three are visible in the picture above.
Separation at the inner nose. The wedge behind each inner tip is lost section. If it grows with velocity, the effective flow area shrinks, local velocity rises, and the element reaches its flooding limit earlier than the face-area calculation suggests. A rounded nose delays it; a sharp one does not.
Pocket recirculation. A pocket that is too shallow shows a closed recirculation cell instead of a slow, draining flow. That cell keeps liquid in suspension and dumps it at the next bend in bursts — which the plant experiences as intermittent carryover rather than steady carryover, and which is very hard to diagnose without the model.
Asymmetry along the channel. The first pass and the last pass rarely see the same velocity. If the last pass is the fastest, the element is effectively shorter than its drawing, and the fix is a longer channel or a lower design velocity, not a deeper pocket.
What to ask a supplier for
If a vane design is offered with CFD support, the request list is short and it is entirely reasonable:
| Deliverable | What it must contain | Why it is asked for |
|---|---|---|
| Geometry and boundary conditions | Channel dimensions, inlet profile, turbulence intensity, wall treatment, fluid properties | Without these the contour cannot be reproduced |
| Mesh independence | Three meshes, DP at each, difference stated | Separates a solution from a picture |
| DP at three flows | 50, 75 and 100% of design, with ζ stated | Field-checkable with a manometer |
| Velocity contours | Mid-plane, plus one plane near the wall | Shows separation and pocket behaviour |
| Droplet tracking | 10 and 30 µm at design and at turndown, with assumptions stated | Explains efficiency without claiming it |
| Test or plant comparison | Rig DP or a comparable installed element | The only real validation |
A supplier who can produce four of these six is doing engineering. A supplier who produces only the first and the fourth is doing layout.
Frequently asked questions
Can CFD prove the vane will meet a 10 micron guarantee?
No. CFD with droplet tracking can show where 10 µm droplets go under stated assumptions, and it is useful for comparing two geometries. The guarantee itself has to come from a test rig or from field data on a comparable element.
Why is the model run at 5 m/s in the channel when the pack is sold on face velocity?
Because the channel is the flow area that exists after the pockets and the frame are subtracted. At an open fraction near 0.61, 5 m/s in the channel is about 3.1 m/s face velocity, which is the number the customer recognises as 70% of the K = 0.152 limit.
Is a 2D slice good enough?
For a first pass on turning and DP, often yes. For pockets, drainage and separation at the nose, no: the pocket is a three-dimensional dead end, and a mid-plane slice hides the recirculation that matters.
What pressure drop should the model show?
60 to 90 Pa for a clean two to three pass element at 5 m/s in air, consistent with the 0.1 to 0.5 kPa band quoted for installed packs once density, liquid load and fouling are added.
Does a good velocity field mean the pack will not flood?
It means the gas side is turning correctly. Flooding is set by liquid load and drainage, which the single-phase field cannot see; a clean field with a shallow pocket still floods.
Related reading
Vane packs and chevron mist eliminators, vane pack design: channel geometry and drainage, what pressure drop to expect, how to read a datasheet, the selection map by duty.
- Gas-Liquid Separation Fundamentals — terminology, separation mechanisms and internal selection
- Technical Data Sheet — material and performance reference data
- All Technical Articles — complete engineering index
More on vane packs and chevron mist eliminators