Entrainment Control in LNG Pre-Cooling Kettle Reboilers: K Values, Disengagement and Shell Diameter
11/15/2026Why a Shorter Kettle Bundle Can Need a Larger Shell: Length, Diameter and Which Area Binds
11/15/2026Two things are commonly assumed about entrainment in a kettle reboiler, and both are wrong in a way that costs money. The first is that a capacity factor is enough: pick a K value, divide the vapour flow by the allowable velocity, get an area, done. The second is that the mist eliminator inside the vessel is a free design parameter that can simply be made larger when the number is short. In a reboiler it cannot. The element lives inside a shell whose diameter, bundle, nozzles, level range and manways were set before anyone asked about droplet capture.
This page covers how entrainment is actually predicted, why a reboiler constrains the element rather than the other way round, and where CFD earns its place in that chain.
How entrainment prediction is structured
The published structure of kettle entrainment prediction is consistent across the main sources, and it is iterative rather than closed-form. It runs in four steps:
- Entrainment ratio. The design specifies a maximum liquid mass per unit vapour mass at the outlet, typically a fraction of a per cent for a machine that must not see liquid. That figure is the target, not a result.
- Vapour velocity in the disengagement space. The velocity is a combination of the produced vapour flow and the actual kettle geometry, meaning the free area above the pool. It is not the nozzle velocity and not the tube-side velocity.
- Critical entrainment velocity. A threshold velocity at which shear force balances gravity and droplets of a given size are no longer retained. It is obtained from semi-empirical and theoretical approaches, and calculating it requires the target entrainment ratio, the vapour flow rate and the physical properties of both phases.
- Iterate the diameter. The kettle diameter is found by iteration, because changing the diameter changes the free area, which changes the velocity, which changes the predicted entrainment ratio.
The authoritative correlations for this are held in HTRI’s proprietary reports on kettle entrainment, referenced in the LNG pre-cooling literature as BK1-2 (analysis and prediction of entrainment and its application to kettle reboiler shell sizing) and BK1-10 (prediction of kettle entrainment). They are not public, and any page quoting a closed-form formula as the HTRI correlation is inventing it. What is public, and what belongs in a process specification, is the structure above and the inputs it needs.
That structure has a consequence worth stating plainly: the prediction depends on the geometry it is applied to. A single capacity factor assumes a uniform approach velocity across the whole free area. In a kettle the vapour does not arrive uniformly, because the heat flux along the bundle is not uniform, so the correlation is being asked to describe a field, not a point. That is why the same element can meet its number on paper and still pass liquid in service.
Why the reboiler does not let you size the element freely
Three constraints bind, and none of them is about droplet capture.
The dome is round. A horizontal element sits as a disc inside a circular shell. Its diameter is limited by the chord available at the height it is installed, not by the shell diameter. On a 3.9 m shell, an element whose plane sits 0.9 m above the shell centre line can be at most 3.46 m across:
| Quantity | Value | Note |
|---|---|---|
| Shell inside diameter | 3.9 m | example, high-pressure propane stage |
| Element plane height above centre | 0.9 m | set by maximum level plus drainage space |
| Maximum element diameter | 3.46 m | chord at that height |
| Element area available | 9.40 m2 | against 11.94 m2 of full shell section |
| Capacity lost to geometry | about 21% | at 0.57 m/s, 5.36 m3/s instead of 6.81 m3/s |
So the shell section buys 6.81 m3/s of capacity and the element actually gets 5.36 m3/s of it. That 21 per cent is not an inefficiency to be engineered away; it is the geometry. The only ways to recover it are to change the element type to one with a higher capacity factor, or to lower the level, which brings the second constraint.
Level and area are the same variable. Raising the liquid level improves the flooded condition of the bundle but moves the element plane upward into a narrower chord, and reduces the disengagement space to the outlet nozzle. On a 3.9 m shell, 0.1 m of rise near that height costs about 0.11 m of element diameter, and the loss accelerates towards the crown: around 0.26 m per 0.1 m once the plane reaches 1.5 m above the centre. A level control band of half a metre is therefore also an area band, and the element must be sized for the worst end of it, not the normal level.
The element must coexist with everything else in the shell. It cannot sit so low that it touches the bundle or blocks circulation; it must drain into the pool on the correct side; it must clear the nozzle projection and the manway, since it has to be installed and removed as modules; and it must survive the two-phase splash zone that the boiling surface produces. Those constraints, not the droplet cut point, usually decide the final layout.
This is the point the LNG pre-cooling literature makes when it treats in-vessel elimination as a design discipline rather than a purchase: the element’s position relative to the vapour generation is what a CFD study is for, and the disengagement space above the mesh to the nozzle is a named constraint, not an afterthought.
What this means in practice
Four rules follow directly, and they are the ones to check before accepting a sizing sheet:
- Do not size the element on the shell’s full section. Size it on the disc available at the installed height, at the highest level in the control band.
- Treat the level band as a capacity parameter. If the level range is wide, the achievable velocity is set by the top of the band, and a tighter level control is worth more than a bigger element.
- Where the geometry is tight, element type earns its money. Inside a fixed chord, a double-pocket vane at 0.305 carries nearly three times the vapour of a vertical mesh at 0.107 for the same area. That is why compact rebollers use combinations rather than bigger pads.
- Verify the local velocity, not the average. The correlation and the capacity factor both act on an average. The vessel acts on the maximum, which sits where the vapour is produced fastest.
Where CFD earns its place, and where it does not
CFD is used in this application for four specific questions, and none of them is “what is the entrainment rate”.
| Question | What CFD answers | What it cannot |
|---|---|---|
| Does vapour short-circuit from a nozzle to the outlet? | Plume trajectory and the position where the element is bypassed | Whether the bypassed liquid actually reaches the compressor |
| Is the element loaded uniformly? | Local velocity distribution across the disc, hot spots at the shell wall | Absolute separation efficiency of the element |
| What level is safe? | Sensitivity of local velocity and freeboard to the level band | The effect of foaming, which is not in most models |
| Does the deflector plate work? | Whether drainage returns to the pool or re-enters the rising flow | The stability of the drainage over time and fouling |
The honest position is that CFD is a distribution tool, not an efficiency tool. It can show you that one third of the element is doing most of the work, or that a nozzle is shooting straight through the middle of it, and those findings change the layout. It cannot tell you the mass of liquid that leaves the vessel unless it is validated against measurement, because the droplet size distribution entering the element, the coalescence inside the media and the film behaviour at the drainage edges are all sub-grid processes.
The verification chain
The defensible way to size this equipment is four layers, each of which covers a gap the others leave:
| Layer | Establishes | Fails when |
|---|---|---|
| Element test data from the supplier | Capacity factor, cut point, pressure drop, drainage behaviour | Tested with air-water, applied to a refrigerant |
| Entrainment correlation for the vessel | Required free area and diameter for the target entrainment ratio | Applied to a geometry with a strongly non-uniform vapour source |
| CFD of the installed arrangement | Local velocity, bypass paths, effect of level and deflector | Boundary conditions taken from the average instead of the load profile |
| Operating data from comparable units | Whether the prediction survives real transients, fouling and start-up | Nobody recorded the level and load when the carryover occurred |
The last layer is the one that is usually missing, and it is the cheapest to fix: a unit that logs level, load and any compressor liquid indication against time can tell you more about the real entrainment behaviour than a third CFD case.
What to require from a CFD deliverable
If a simulation is part of the justification, these are the items that decide whether it is evidence or decoration:
- Boundary conditions from the actual vapour load profile, not a uniform inlet over the bundle. A uniform source models a vessel that does not exist.
- Mesh independence shown, with the local velocity at the element reported at two mesh densities.
- Residual and convergence criteria stated, and the case run to those criteria rather than to a wall-clock limit.
- Sensitivity runs: at least 70 per cent, 100 per cent and 110 per cent load, and the top and bottom of the level band.
- Maximum local velocity reported alongside the average, with its location identified.
- Validation case against a measured arrangement, even if it is a small air-water rig. Without one the output is a picture, not a prediction.
- Review by the element supplier, since the media behaviour the model cannot resolve is exactly what the supplier has tested.
The length and diameter consequences of a shorter bundle, stage by stage, are set out in why a shorter kettle bundle can need a larger shell.
Reference
The process context, capacity factors and the treatment of in-vessel elimination follow Knoepfler, Buffet, El Hajal, Lang, Provost, Rambure and Redjem Saad, LNG2023, Vancouver, paper 3.2.1, whose literature cites HTRI reports BK1-2 and BK1-10 for the entrainment correlations and the model of critical entrainment velocity used here.
Frequently Asked Questions
Where do the kettle entrainment correlations come from?
Why can a mist eliminator not simply be made larger inside a reboiler?
How does the liquid level affect separation capacity?
What can CFD tell you that an entrainment correlation cannot?
What should be required of a CFD study submitted with a chiller design?
- Gas-Liquid Separation Fundamentals — terminology, separation mechanisms and internal selection
- Technical Data Sheet — material and performance reference data
- All Technical Articles — complete engineering index
If you are working on a replacement
Most of the work behind an article like this is a replacement inside an existing vessel, where the available dimensions decide more than the nominal duty. See the process data needed to size and select it, the scope from data review through to delivery and what has to be supplied before a price is issued.
More on wire mesh demisters and demister pads
- How Does a Wire Mesh Demister Work? A Complete Guide – the guide that covers this device family end to end
- Demister Sizing: Why Western and Chinese Conventions Give Different Diameters
- Why the Same Demister Duty Gives Different Diameters: Five Conventions That Move the Answer
- Reboiler Mist Eliminators in Ethylene, C3 Splitter Heat Pumps and Refrigeration Chillers
- Entrainment Control in LNG Pre-Cooling Kettle Reboilers: K Values, Disengagement and Shell Diameter
Not sure which technology fits the duty at all? Which Mist Eliminator or Coalescer Do You Need? A Selection Map by Duty compares all four on droplet cut point, pressure drop and fouling tolerance.