11/09/2026To size a mist eliminator you need one number first: the maximum allowable vapor velocity. Calculate it with the Souders-Brown equation, umax = K × √((ρL − ρV) / ρV), then design at 60–75% of that value. Divide your actual volumetric vapor flow by the design velocity to get the required face area, and the vessel or pad diameter follows from the area.
Everything else — mesh density, bed thickness, drainage arrangement, material grade — is decided after the diameter is fixed. Getting the velocity wrong is the single most common reason a demister underperforms in service, and it is also the most expensive mistake because it means a new vessel or a redesigned internal.
The coefficient used here is the Western separator value; a Chinese design calculation for a thicker pad can give a vessel 47 per cent smaller in diameter for the same duty. The reconciliation is in demister sizing conventions.
Step 1 — Establish the vapor and liquid properties
Sizing starts with the physical properties at operating conditions, not at standard conditions. Vapor density at 1 atm and 20 °C is not the number you use for a column overhead running at 180 °C and 4 bar. Collect:
- Vapor mass flow at minimum, normal and maximum case
- Operating pressure and temperature for each case
- Vapor density ρV and liquid density ρL at those conditions
- Liquid mass loading, expressed as kg liquid per kg vapor or as volumetric load per unit area
- Droplet size distribution if available, or the expected generation mechanism (condensation, entrainment from a tray, spray from a nozzle, scrubber carryover)
The density ratio drives everything. A high pressure column with a dense vapor gives a low velocity and a small diameter. A vacuum column with a very light vapor gives a high velocity and a large diameter — which is why vacuum demisters are often surprisingly big.
Step 2 — Calculate the maximum allowable velocity
Use the Souders-Brown form:
umax = K × √((ρL − ρV) / ρV)
The capacity factor K is empirical and depends on the internal type and the service severity. The following values are conventional starting points for vertical flow internals:
| Internal type | Typical K (ft/s) | Typical K (m/s) | Notes |
|---|---|---|---|
| Knitted wire mesh, standard service | 0.35 | 0.107 | Normal liquid loading, clean service |
| Knitted wire mesh, heavy liquid load or fouling | 0.25–0.30 | 0.076–0.091 | Lower K to preserve drainage |
| Knitted wire mesh, vacuum service | 0.20–0.25 | 0.061–0.076 | Very low vapor density, avoid flooding |
| Vane pack / chevron | 0.50–0.60 | 0.152–0.183 | Higher velocity tolerated, coarser droplets |
| Fiberbed candle filter | sized on face velocity 0.1–0.5 m/s | Dominated by media grade and required outlet purity | |
These are starting values. Any vendor datasheet, any proprietary correlation, and any previous operating experience on the same service should override them. K values assume a reasonably uniform velocity profile across the pad — if the inlet is close to the pad or the vessel has poor flow distribution, derate.
Step 3 — Choose the design velocity
Never design at umax. Design at 60–75% of it. The margin covers:
- Turndown and upset conditions where flow rises above the normal case
- Velocity maldistribution from a badly placed inlet nozzle
- Liquid hold-up as the pad wets and fouls, which raises pressure drop and reduces the effective open area
- Future capacity creep, which almost always happens
Where the liquid loading is high, the liquid is viscous, or the process is prone to foaming, use the lower end of the band. Where the service is clean gas with light liquid load, 75% is acceptable.
Step 4 — Convert to area and diameter
Volumetric vapor flow at operating conditions:
Q = m / ρV
Required face area:
A = Q / udesign
Then for a round vessel or pad:
D = √(4A / π)
Worked example
Take a vent line handling 10,000 kg/h of air at 60 °C and atmospheric pressure, carrying water droplets, with a vertical knitted wire mesh demister required.
| Step | Calculation | Result |
|---|---|---|
| Vapor density (air, 60 °C, 1 atm) | ρV ≈ 1.06 kg/m³ | 1.06 kg/m³ |
| Liquid density (water, 60 °C) | ρL ≈ 983 kg/m³ | 983 kg/m³ |
| Density term | √((983 − 1.06) / 1.06) | 30.4 |
| Maximum velocity | 0.107 × 30.4 | 3.25 m/s |
| Design velocity (70% of max) | 0.70 × 3.25 | 2.28 m/s |
| Volumetric flow | 10,000 / 1.06 | 9,434 m³/h = 2.62 m³/s |
| Face area | 2.62 / 2.28 | 1.15 m² |
| Diameter | √(4 × 1.15 / π) | 1.21 m |
A 1.2 m diameter mesh pad at roughly 100–150 mm bed thickness in SS316L would be the outcome. Note that if the same duty were handled by a vane pack at K = 0.15 m/s (about 0.5 ft/s), the design velocity would be higher and the diameter smaller — the trade is coarser droplet capture but a more compact unit.
Step 5 — Set the bed thickness and density
Diameter alone does not fix performance. Bed thickness and mesh density decide the capture efficiency for fine droplets and the pressure drop you will live with:
| Mesh density | Bed thickness | Service | Expected pressure drop |
|---|---|---|---|
| 80–120 kg/m³ | 100 mm | High liquid load, dirty gas, fouling risk | 0.1–0.2 kPa |
| 140–180 kg/m³ | 150 mm | General industrial service | 0.15–0.3 kPa |
| 190–220 kg/m³ | 200–300 mm | Fine droplet capture, high efficiency | 0.3–0.6 kPa |
Step 6 — Check the drainage design
A correctly sized pad still fails if liquid cannot leave it. Confirm:
- There is a clear drainage path from the pad to the vessel low point, without a liquid seal that would block flow
- The pad is not sitting directly on a support that closes off the bottom face
- For horizontal flow, there is a drainage pocket and the pad is installed with the correct corrugation orientation
- Vapor velocity through the drainage gap is not high enough to re-entrain the draining liquid
What to send for a datasheet
If you want a sized element quoted, the six numbers that matter most are: maximum vapor mass flow, operating pressure, operating temperature, liquid loading, allowable pressure drop, and required outlet concentration. Vessel inside diameter and orientation let us confirm the pad geometry matches what you can physically install. See our knitted wire mesh demister range and technical data sheet, or request a sizing calculation.
Frequently Asked Questions
How do you calculate the diameter of a demister?
Calculate the maximum allowable vapor velocity with the Souders-Brown equation, u_max = K times the square root of (liquid density minus vapor density) divided by vapor density. Divide the actual volumetric vapor flow by a design velocity of 0.6 to 0.75 of u_max to get the required mesh area, then convert the area to a diameter.
What K value should be used for a wire mesh demister?
A capacity factor K of about 0.35 ft/s (0.107 m/s) is the conventional starting point for vertical knitted wire mesh demisters in normal service. Use a lower K of 0.25 to 0.30 ft/s where liquid loading is high, the liquid is viscous or foaming, or vacuum service makes the vapor density very low. Vane packs tolerate a higher K of roughly 0.5 to 0.6 ft/s, and fiberbed elements are sized on face velocity rather than K.
Why do I need to design below the flooding velocity?
At the flooding velocity the vapor shear is strong enough to hold liquid in the bed instead of letting it drain. Once that happens the pad re-entrains liquid, pressure drop rises sharply and outlet loading increases instead of falling. Designing at 60 to 75 percent of the Souders-Brown maximum leaves margin for turndown, upsets and fouling.
What gas data do I need before sizing a demister?
You need mass or volumetric flow at minimum, normal and maximum conditions, operating pressure and temperature, vapor density and liquid density at those conditions, liquid loading, expected droplet size distribution, allowable pressure drop and the required outlet concentration. Vessel diameter and orientation determine whether the pad is round, rectangular or segmented.
- Gas-Liquid Separation Fundamentals — terminology, separation mechanisms and internal selection
- Technical Data Sheet — material and performance reference data
- All Technical Articles — complete engineering index
If you are working on a replacement
A wire mesh pad performs only if it seals to the shell all round, so the measured inside diameter matters as much as the mesh density. See the process data needed to size and select it, what can and cannot be compressed on an urgent replacement and the scope from data review through to delivery.
More on wire mesh demisters and demister pads
- How Does a Wire Mesh Demister Work? A Complete Guide – the guide that covers this device family end to end
- Why the Same Demister Duty Gives Different Diameters: Five Conventions That Move the Answer
- Reboiler Mist Eliminators in Ethylene, C3 Splitter Heat Pumps and Refrigeration Chillers
- Why a Shorter Kettle Bundle Can Need a Larger Shell: Length, Diameter and Which Area Binds
- Entrainment Prediction in Kettle Reboilers, Why the Element Is Not Free to Size, and What CFD Is Actually For
Not sure which technology fits the duty at all? Which Mist Eliminator or Coalescer Do You Need? A Selection Map by Duty compares all four on droplet cut point, pressure drop and fouling tolerance.