Coalescer Internals for Alkylation Unit Acid Settlers: Wire Mesh, Corrugated Plates and Distribution Plates
10/30/2026Double-Filament Wire Mesh Coalescer for Hydrogen Peroxide Extraction
10/30/2026Introduction: Where Liquid-Liquid Separation Sits in a Polycarbonate Plant
Most polycarbonate (PC) is produced by interfacial polymerization of bisphenol A (BPA) and phosgene in methylene chloride (DCM), with triethylamine as catalyst and a caustic aqueous phase to keep the BPA in its reactive phenolate form. After the reactors, the crude product is a viscous organic solution of PC in DCM (typically 15–25 wt% resin) that must be purified before the polymer can be isolated, devolatilized and pelletized.
Purification is carried out in a wash train, normally a series of liquid-liquid settlers and centrifuges:
- Caustic wash (5–10% NaOH) to strip residual BPA, phenolate and catalyst residues from the organic phase.
- Acid wash (dilute HCl) to neutralize residual caustic and remove triethylamine catalyst.
- Final water wash to remove residual salts and acid before solvent recovery and devolatilization.
Each stage is a liquid-liquid separation duty in which the continuous phase is the PC/DCM solution and the dispersed phase is an aqueous stream. Separation performance directly sets product quality and plant economics. Carryover of caustic or acid into the next stage consumes reagent and can hydrolyse polymer; residual amine left in the resin discolours the product and can corrode downstream equipment; and aqueous droplets carried into devolatilization flash off as steam, upsetting vacuum systems and extruder performance. On the solvent recovery side, DCM dissolved or entrained in the aqueous effluent must be recovered before the water goes to treatment — both for environmental compliance and because every kilogram of DCM lost is a raw-material cost.
The Separation Challenge in PC Wash Trains
On paper, DCM and water separate easily: the density difference is large. In practice, four effects combine to make PC wash separation one of the more demanding coalescing duties in the chemical industry.
- Small droplet size. Agitation in reactors, pumps, valves and especially centrifuges generates aqueous droplets in the 5–50 micron range. Stokes’ law settling velocity scales with the square of droplet diameter, so a 10 micron droplet settles roughly 100 times more slowly than a 100 micron droplet.
- Viscosity of the continuous phase. Settling velocity is inversely proportional to continuous-phase viscosity. As polymer concentration rises through the train, the organic phase can reach 100–500 cP — an order of magnitude above water — so droplets that would settle in seconds in a water-continuous system may take hours.
- Wetting behaviour. DCM wets metals and most plastics readily. Aqueous droplets therefore tend to adhere to internals and to each other’s films rather than drain cleanly, and coalesced water can re-entrain if the surface is not designed to release it.
- Emulsion tendency. Residual BPA salts, catalyst residues and interfacial films stabilise emulsions. High-shear devices such as centrifuges can make the emulsion finer, not coarser, so the separation duty handed to downstream equipment can be worse than expected.
The practical consequence is that no single device handles the full droplet spectrum economically. A staged approach — bulk removal, agglomeration, then polish — is the standard solution, and passive coalescer internals are the workhorse of each stage.
Stage 1: Inclined Plate (Lamella) Coalescer for Bulk Free Aqueous Removal
The first stage after the reactor and wash mixers is a settler fitted with an inclined plate pack. The plates provide a large projected settling area in a compact vessel: a plate pack with 50–100 mm pitch and 45–60° inclination can multiply the effective settling area of a horizontal drum several-fold, allowing droplets in the 50–200 micron range to reach a surface and coalesce within a realistic residence time.
Plate inclination is chosen so that coalesced aqueous films drain counter-current to the rising droplets and report to a collection zone rather than being re-entrained. Smooth, low-surface-energy plate surfaces help the aqueous phase release from the plate; in DCM service this matters more than in water-continuous systems because the organic phase preferentially wets metal.
Why use plates before centrifuges? The plate pack removes the bulk of free water at negligible pressure drop and with no shear. That reduces the water load on the centrifuge, improves centrifuge capacity and stability, and — critically — means the high-shear device sees a leaner feed, so the emulsion it generates is less fine. In many revamps, adding or upgrading a plate pack upstream of an existing centrifuge is the lowest-cost way to recover capacity.
Stage 2: Knitted Wire Mesh Coalescer for 10–50 Micron Droplets
After bulk settling, the organic phase still carries aqueous droplets in the 10–50 micron range. These are too small for gravity settling at 100–500 cP but are ideal candidates for a knitted wire mesh coalescer. The mesh — typically 100–300 mm deep, with high void fraction and a tortuous flow path — forces droplets into repeated contact with the wire surface. Droplets collect on the wires, coalesce into films and larger drops, and release when drag forces exceed the holding force.
Mesh outperforms simple settling in DCM service for three reasons: the path length for droplet interception is short, so even slow-settling droplets reach a surface; the coalesced drops are large enough (hundreds of microns) to settle quickly in the downstream calming zone; and the open structure gives low pressure drop and low fouling tendency compared with fine-pore media.
Material selection is driven by the wash stage. SS316L is standard for the caustic and water washes. For the acid wash and any chloride-bearing service, Hastelloy C276 or an equivalent nickel alloy is preferred to avoid pitting and stress corrosion, particularly where residual HCl and chlorides can concentrate in stagnant zones. Mesh style, wire diameter and surface treatment (for example, treatments that promote aqueous film release in an organic-continuous system) are selected per stage rather than applied uniformly across the train.
Stage 3: Cartridge / Fiberbed Polish for 2–10 Micron Droplets
The final separation duty is polishing the organic phase to clarity before devolatilization and extrusion. Droplets in the 2–10 micron range are not removed reliably by mesh alone, and any residual aqueous phase here becomes steam in the devolatilizer, causing vacuum instability, gel formation and colour bodies in the final resin.
Cartridge or fiberbed elements — banks of fibre media in a housing, arranged for axial or radial flow — remove these fine droplets by interception, inertial impaction and direct capture on fine fibres, with the coalesced liquid draining to a sump. Cartridge banks are sized for the turndown range of the line and are typically protected by the upstream mesh stage so that solids and gross water do not blind the fine media. Where product colour is critical, the polish stage is often the difference between on-spec and off-spec resin.
Solvent Recovery: DCM-in-Water Coalescing Before Wastewater
The aqueous streams from the wash train — caustic, acid and water — carry dissolved and entrained DCM. Dissolved DCM is normally handled by stripping, but entrained DCM droplets must be coalesced first or they will carry through to the stripper and the wastewater treatment plant, causing permit exceedances and solvent loss.
On the water side the phases are inverted: water is continuous and DCM is dispersed. Wire mesh coalescers or inclined plate packs installed in the aqueous line agglomerate DCM droplets so that a solvent layer can be decanted and returned to the process. Because the density difference is favourable and the aqueous phase viscosity is low, plate packs and mesh handle this duty efficiently; the design focus is on turndown, solids tolerance and avoiding short-circuiting rather than on fine-droplet capture. Recovering this DCM typically pays back the internals quickly through reduced solvent make-up and lower COD load on the treatment plant.
Typical Internals Arrangement in a PC Wash Settler
A well-designed coalescing settler for PC service combines the stages in one vessel or in a short series of vessels:
- Inlet distributor — dissipates mixer energy and spreads flow across the vessel section, preventing jetting and short-circuiting.
- Calming baffle — establishes plug flow and allows the largest droplets to rise before the plate pack.
- Inclined plate pack — bulk removal of free aqueous phase.
- Knitted wire mesh pad — agglomeration of 10–50 micron droplets, with a downstream settling zone and interface control.
- Cartridge bank — final polish of the organic phase to 2–10 micron removal, protecting devolatilization.
Interface level control, drain points at each stage and provisions for cleaning are as important as the media themselves; in DCM service, stagnant zones are where corrosion and emulsion build-up begin.
Why Passive Internals Matter in Polycarbonate Service
Centrifuges are widely used in PC wash trains and can be effective, but they introduce shear at the feed and bowl, which can regenerate fine emulsion and make the downstream separation harder. Passive coalescer internals have no moving parts, consume no power, and introduce no shear: they separate by surface chemistry and gravity, so the droplet size distribution leaving the device is coarser than the one entering it. In corrosive DCM/acid service, the absence of seals, bearings and motors also removes a maintenance burden and a leakage risk. For these reasons, many plants use coalescer internals as the primary separation device and reserve centrifuges for duties where their compactness is essential — or use coalescers upstream to protect the centrifuges.
Influent Separation supplies wire mesh coalescer media, inclined plate packs and cartridge elements for polycarbonate wash settlers and solvent recovery coalescers, engineered for DCM service and matched to each stage of the wash train.
Related Products
- Inclined / Corrugated Plate Coalescer Media
- Knitted Wire Mesh Coalescer Media
- Fiberbed / Cartridge Coalescer Elements
- Distribution Plates and Calming Baffles
Frequently Asked Questions
Why is liquid-liquid separation in polycarbonate production harder than in a hydrocarbon settler?
What droplet size should the coalescer produce for the settler to work?
How does temperature affect the separation?
What does an emulsion band at the interface indicate?
Which measurements prove the internals are doing their job?
- Technical Data Sheet — material and performance reference data
- All Technical Articles — complete engineering index
If you are working on a replacement
Coalescer media and plate packs are usually replaced as a set with their support frame, so the interface dimensions are fixed before the media grade is chosen. See the process data needed to size and select it, how fabrication and inspection run and what can and cannot be compressed on an urgent replacement.
More on coalescer internals and liquid-liquid separation
- Aftermarket Coalescer Cartridges: Cross-Reference and Replacement Guide – the guide that covers this device family end to end
- Aftermarket Coalescer Cartridges for Produced Water Treatment: OEM-Equivalent
- Hastelloy and Monel Coalescer Internals: Special Alloy Replacement for Corrosive Service
- Cross-Reference Guide: Replacing Major Brand Coalescer Internals
- Produced Water Coalescers for Offshore Platforms: Meeting IMO Oil-in-Water Discharge Limits
Not sure which technology fits the duty at all? Which Mist Eliminator or Coalescer Do You Need? A Selection Map by Duty compares all four on droplet cut point, pressure drop and fouling tolerance.
