Design of a Wire Mesh Demister
03/19/2023Short answer: the mist eliminator in a marine scrubber is there to stop washwater droplets that carry soot, sulphate and residual sulphur species from leaving the absorber. It is selected on fouling and corrosion behaviour as much as on droplet efficiency, because a high efficiency element that fouls in two weeks performs worse than a simpler one that stays clean.
What the element has to handle
| Condition | Effect on the eliminator |
|---|---|
| High washwater liquid load | Favours a blade-type internal with positive drainage over a mesh pad |
| Soot and particulate in the washwater | Deposits blind fine passages and raise pressure drop |
| Sulphate and carbonate scaling | Hard deposits that cannot be washed off without access |
| Seawater chlorides at 50 to 80 °C | Rules out standard stainless; requires super duplex, 6Mo, nickel alloy or thermoplastic |
| Continuous operation with no maintenance window | Design must tolerate fouling and provide wash coverage over the whole face |
Open loop, closed loop and hybrid
Open loop: seawater is sprayed into the absorber, and the effluent is treated and discharged. Chloride content is high, alkalinity provides natural buffering, and the discharge is governed by the applicable washwater criteria. Corrosion is the dominant material driver.
Closed loop: freshwater with sodium hydroxide circulates through a treatment unit. pH is higher, which changes scaling behaviour, and the liquor is more aggressive to some alloys in a different way than seawater. Fouling tends to be sulphate and carbonate based rather than biological.
Hybrid: open loop in open waters and closed loop in sensitive areas. The eliminator must then work across both chemistries, which usually pushes the material choice to the more resistant option.
Internal type selection
Because liquid load is high and fouling is expected, vane or chevron type internals are common in scrubber absorbers, with a mesh pad used where the load is lower and the required cut is finer. The trade-off between blade types and mesh is set out in Vane Packs and Chevron Mist Eliminators.
Where the outlet has to be very clean, a two-stage arrangement is used: a blade stage for bulk liquid, then a mesh or fiberbed stage for polishing. Overloading the fine stage with bulk liquid is the usual reason a scrubber outlet fails to meet its limit.
Fouling management
- Wash coverage must reach the whole face, not just the centre; partial washing leaves a fouled zone that distorts flow.
- Provide access for manual cleaning during planned maintenance; deposits that harden cannot be removed by spray alone.
- Prefer generous passage size over maximum efficiency where soot loading is high.
- Trend pressure drop continuously: a rising trend is the earliest indicator of fouling, well before carryover appears.
Pressure drop and fan power
The eliminator sits in the exhaust path, so its pressure drop is paid continuously in fan power. A fouled element can multiply the pressure drop, and the resulting power penalty is often larger than the value of the extra efficiency that caused the fouling. This is the same trade-off discussed for cooling towers in Cooling Tower Drift Eliminators.
Discharge considerations
Washwater is discharged under the applicable IMO washwater criteria, which cover acidity, polycyclic aromatic hydrocarbons, turbidity and nitrate depending on the regime and the area of operation. The eliminator does not change the dissolved load in the washwater, but it does keep droplets from being carried into the exhaust, which is a separate and visible problem. Compliance obligations are summarised on the marine industry page, and the regulatory angle in Mist Eliminators for Marine Scrubbers: EGCS Compliance.
Send the scrubber type, exhaust gas flow, washwater rate, operating temperature, fuel sulphur limit and available pressure drop and we will propose an internal type, material and expected performance with the fouling assumption stated.
Frequently Asked Questions
Why do marine scrubbers need a mist eliminator?
Which material is used in seawater scrubber mist eliminators?
What is the main operating problem?
How does open loop versus closed loop change the design?
- Gas-Liquid Separation Fundamentals — terminology, separation mechanisms and internal selection
- Technical Data Sheet — material and performance reference data
- All Technical Articles — complete engineering index
If you are working on a replacement
Most of the work behind an article like this is a replacement inside an existing vessel, where the available dimensions decide more than the nominal duty. See the process data needed to size and select it, the scope from data review through to delivery and what has to be supplied before a price is issued.
More on wire mesh demisters and demister pads
- How Does a Wire Mesh Demister Work? A Complete Guide – the guide that covers this device family end to end
- Demister Sizing: Why Western and Chinese Conventions Give Different Diameters
- Why the Same Demister Duty Gives Different Diameters: Five Conventions That Move the Answer
- Reboiler Mist Eliminators in Ethylene, C3 Splitter Heat Pumps and Refrigeration Chillers
- Why a Shorter Kettle Bundle Can Need a Larger Shell: Length, Diameter and Which Area Binds
Not sure which technology fits the duty at all? Which Mist Eliminator or Coalescer Do You Need? A Selection Map by Duty compares all four on droplet cut point, pressure drop and fouling tolerance.