Aftermarket Fiberbed Candle Filters for Alkylation Units: OEM-Equivalent Performance

Cross-Reference Guide: Replacing Major Brand Coalescer Internals
10/31/2026
Hastelloy and Monel Coalescer Internals: Special Alloy Replacement for Corrosive Service
10/31/2026
Cross-Reference Guide: Replacing Major Brand Coalescer Internals
10/31/2026
Hastelloy and Monel Coalescer Internals: Special Alloy Replacement for Corrosive Service
10/31/2026

Short answer: replacing a fiberbed candle in an alkylation acid settler is not a dimensional exercise alone. The media grade and its density gradient, the seal arrangement and the pressure drop at design flow all have to match, otherwise the replacement fits but does not perform. The measurable criteria are set out below.

What “OEM-equivalent” has to mean in practice

A fiberbed candle removes sub-micron acid mist by passing the gas through a graded glass fibre bed. Capture happens in the fine upstream layer, and the coarser downstream layers drain the collected liquid. That gradient is the functional core of the element: a candle built with uniform media can pass a dimensional inspection and still fail on pressure drop and drainage.

Attribute What has to match How it is verified
Physical envelope Outside diameter, overall length, flange or bayonet size, bolt pattern Measured against the vessel drawing or the removed element
Media grade Fibre type and the density gradient through the bed Section a used element, or back-calculate from flow and allowable pressure drop
Seal Gasket material, seating face and pre-load Leak test on the seal before fitting
Pressure drop Value at the design gas flow and operating conditions Airflow test at the works, compared with commissioning data
Drainage Liquid path from the bed to the outlet without re-entrainment Flow test with liquid present, checking for carryover

Pressure drop expectation

Fiberbed elements run at substantially higher pressure drop than a mesh pad, typically in the range of 0.5 to 2 kPa at design flow depending on media grade and bed thickness. That is the price of sub-micron capture. A replacement that shows materially less pressure drop than the original is not necessarily better: it may be coarser media that lets acid mist through, which shows up as carryover rather than as a pressure reading.

How the cross-reference is done

  1. Record the vessel, the number of candles, the gas flow and the operating pressure and temperature.
  2. Measure the removed element: outside diameter, length, fixing type, and the position of any seal face.
  3. Section one used candle to read the media gradient, or use the original pressure drop data to back-calculate the grade.
  4. Confirm the allowable pressure drop budget with the blower or compressor capability.
  5. Define the materials for the acid service, including the seal and any wetted metal parts.
  6. Specify the acceptance test: dimensions, visual, seal leak test, airflow test.

Installation points that decide whether it works

  • Seat the candle on a clean face; residual gasket material from the old element causes a leak path.
  • Respect the pre-load; over-tightening distorts the seal and under-tightening leaves a bypass.
  • Check that the candle does not foul the vessel internals during insertion.
  • After fitting, confirm the pressure drop at start-up against the expected value before the unit is brought to full rate.

Failure modes after replacement

Symptom Likely cause
Carryover unchanged Media too coarse, seal bypass, or wrong candle position
Pressure drop higher than expected Denser media, shorter flow area, or gasket protruding into the flow
Pressure drop rising over weeks Acid sludge accumulating in the bed, or liquid not draining
Media shedding downstream Fibre damaged in handling or a support layer missing

Background on the acid settler arrangement is in Coalescer Internals for Alkylation Unit Acid Settlers, and on the fiberbed principle in Chlorine Gas Drying with Fiber Bed Mist Eliminators.

Send the vessel data, gas flow, operating conditions, photographs and dimensions of the removed candle and the allowable pressure drop, and we will return a written equivalence statement covering media grade, envelope, seal and expected pressure drop. Pricing is quoted separately by our sales team after the technical review.

Frequently Asked Questions

What makes a fiberbed candle OEM-equivalent?

Four things have to match: the physical envelope (outside diameter, length, flange or bayonet fixing), the media grade and its density gradient, the seal arrangement, and the pressure drop at the design flow. A candle that fits but has a different media gradient will not repeat the original performance.

Can the media grade be identified from an old candle?

Rarely from the outside. A used candle can be sectioned to reveal the fibre type and the density gradient, and the pressure drop at a known flow gives a cross-check. Where no data exists, the design flow and allowable pressure drop are used to back-calculate a media specification.

Why does a replacement candle sometimes show higher pressure drop?

Usually a denser media, a different density gradient, or a shorter effective flow area. It can also be a gasket that protrudes into the flow path. Compare the pressure drop at the same flow against the original commissioning data before accepting the unit.

How is the candle checked before shipment?

Dimensional check against the drawing, visual inspection of the media for gaps or delamination, a leak test on the seal, and an airflow test to confirm pressure drop at the design flow.