10/31/2026Short answer: replacing a fiberbed candle in an alkylation acid settler is not a dimensional exercise alone. The media grade and its density gradient, the seal arrangement and the pressure drop at design flow all have to match, otherwise the replacement fits but does not perform. The measurable criteria are set out below.
What “OEM-equivalent” has to mean in practice
A fiberbed candle removes sub-micron acid mist by passing the gas through a graded glass fibre bed. Capture happens in the fine upstream layer, and the coarser downstream layers drain the collected liquid. That gradient is the functional core of the element: a candle built with uniform media can pass a dimensional inspection and still fail on pressure drop and drainage.
| Attribute | What has to match | How it is verified |
|---|---|---|
| Physical envelope | Outside diameter, overall length, flange or bayonet size, bolt pattern | Measured against the vessel drawing or the removed element |
| Media grade | Fibre type and the density gradient through the bed | Section a used element, or back-calculate from flow and allowable pressure drop |
| Seal | Gasket material, seating face and pre-load | Leak test on the seal before fitting |
| Pressure drop | Value at the design gas flow and operating conditions | Airflow test at the works, compared with commissioning data |
| Drainage | Liquid path from the bed to the outlet without re-entrainment | Flow test with liquid present, checking for carryover |
Pressure drop expectation
Fiberbed elements run at substantially higher pressure drop than a mesh pad, typically in the range of 0.5 to 2 kPa at design flow depending on media grade and bed thickness. That is the price of sub-micron capture. A replacement that shows materially less pressure drop than the original is not necessarily better: it may be coarser media that lets acid mist through, which shows up as carryover rather than as a pressure reading.
How the cross-reference is done
- Record the vessel, the number of candles, the gas flow and the operating pressure and temperature.
- Measure the removed element: outside diameter, length, fixing type, and the position of any seal face.
- Section one used candle to read the media gradient, or use the original pressure drop data to back-calculate the grade.
- Confirm the allowable pressure drop budget with the blower or compressor capability.
- Define the materials for the acid service, including the seal and any wetted metal parts.
- Specify the acceptance test: dimensions, visual, seal leak test, airflow test.
Installation points that decide whether it works
- Seat the candle on a clean face; residual gasket material from the old element causes a leak path.
- Respect the pre-load; over-tightening distorts the seal and under-tightening leaves a bypass.
- Check that the candle does not foul the vessel internals during insertion.
- After fitting, confirm the pressure drop at start-up against the expected value before the unit is brought to full rate.
Failure modes after replacement
| Symptom | Likely cause |
|---|---|
| Carryover unchanged | Media too coarse, seal bypass, or wrong candle position |
| Pressure drop higher than expected | Denser media, shorter flow area, or gasket protruding into the flow |
| Pressure drop rising over weeks | Acid sludge accumulating in the bed, or liquid not draining |
| Media shedding downstream | Fibre damaged in handling or a support layer missing |
Background on the acid settler arrangement is in Coalescer Internals for Alkylation Unit Acid Settlers, and on the fiberbed principle in Chlorine Gas Drying with Fiber Bed Mist Eliminators.
Send the vessel data, gas flow, operating conditions, photographs and dimensions of the removed candle and the allowable pressure drop, and we will return a written equivalence statement covering media grade, envelope, seal and expected pressure drop. Pricing is quoted separately by our sales team after the technical review.
Frequently Asked Questions
What makes a fiberbed candle OEM-equivalent?
Can the media grade be identified from an old candle?
Why does a replacement candle sometimes show higher pressure drop?
How is the candle checked before shipment?
- Gas-Liquid Separation Fundamentals — terminology, separation mechanisms and internal selection
- Technical Data Sheet — material and performance reference data
- All Technical Articles — complete engineering index
If you are working on a replacement
Fiberbed elements are the most sensitive of the internal types to bed thickness and to what condenses inside the media, which is why the data behind the selection has to be explicit. See the process data needed to size and select it, how fabrication and inspection run and the scope from data review through to delivery.
More on fiberbed mist eliminators
- Fiberbed vs Wire Mesh Demister: Which Mist Eliminator Do You Need? – the guide that covers this device family end to end
- OEM-Equivalent Fiberbed Candle Replacement for Sulfuric Acid Plants
Not sure which technology fits the duty at all? Which Mist Eliminator or Coalescer Do You Need? A Selection Map by Duty compares all four on droplet cut point, pressure drop and fouling tolerance.