Demister Sizing: Why Western and Chinese Conventions Give Different Diameters
11/15/2026Acid mist elimination in a WSA plant: the square ETFE element and the tube-end mesh roll
11/26/2026Almost every mist eliminator is sized at one point, the design flow, and then operated along a curve. A propane chiller, a vacuum column or a compressor suction drum may spend most of its life between 40 and 70 per cent of that design flow, and the incidents that actually hurt – carryover into a compressor, salt building up on a pad, a gummed vane pack – usually happen at the low end of the range rather than at the point the datasheet was written for.
- If the unit is clean at design flow and carries over when the plant comes down → Where the failure really starts: upstream distribution
- If you have to accept a vane pack across a wide flow range → Why the vane pack loses cut size first
- If the DP gauge reads low and you have concluded the pad is clean → What the pressure drop reading does not tell you
- If you are writing or reviewing the datasheet → What to write into the datasheet
Low flow is a design condition, not an off-design accident
A separator does not have an efficiency. It has an efficiency curve, with a window inside which the device does what the datasheet promised and two edges outside it. The upper edge is flooding and re-entrainment: the gas drags the collected liquid back off the element faster than it can drain. The lower edge is quieter and less often specified: the gas no longer carries enough momentum to capture the droplets it was bought to remove, and the flow no longer distributes itself evenly across the available area.
Both edges move with the same variable, so a device sized comfortably against flooding is not automatically comfortable at turndown. It is common to see a pad selected at 70 per cent of the Souders-Brown maximum velocity, which leaves a 30 per cent margin at the top and no stated requirement at the bottom. When the plant runs at half rate, the pad operates at 35 per cent of its maximum, and nobody has checked what that does to the cut size.
Why the vane pack loses cut size first
Vane and cyclone separation is inertial. A droplet is captured when it cannot follow the gas round a bend, and that condition is described by the Stokes number: the ratio of the droplet’s stopping distance to the characteristic dimension of the passage. Collection efficiency at a given geometry collapses onto a single curve against Stokes number, which means the droplet size collected at constant efficiency scales as one over the square root of velocity.
The consequence is arithmetic, not opinion. Halve the velocity and the cut size grows by about 1.41; take the unit to a quarter of design flow and the cut size doubles. A vane pack with a 10 micron cut at design flow has roughly a 14 micron cut at half flow and a 20 micron cut at quarter flow. Droplets in the 15 to 40 micron band, which the pack was bought to remove, pass through at the low end of the range with no alarm and no visible change on the gauge.
There is a second effect that does not appear in the Stokes number. At low velocity the liquid film on the blades loses the shear that keeps it spread over the surface, and the film becomes patchy: wet channels and dry channels side by side. The dry channels stop capturing altogether, because there is no film for a droplet to merge into, and the captured liquid that does arrive drains more slowly through the gutters. A pack that is perfectly uniform at design flow can be half dry at 30 per cent flow.
The mesh pad behaves differently, and that hides the problem
Knitted mesh is also an inertial device, but its fibres are an order of magnitude finer than a vane passage, so interception and diffusion keep contributing after impaction has fallen away. The practical effect is a flatter curve at the low end: a standard pad rated at 99 per cent removal above 3 to 10 microns at design velocity may still hold most of that at half velocity, with the cut size drifting from about 4 to 8 microns.
That flatness is useful, but it also hides the failure. Because the pad keeps working at low load, nobody looks at it, and two things then go wrong quietly. First, the pressure drop falls with the square of flow, so the gauge reads a quarter of its design value at half flow and the operator reads that as a clean pad. Second, a pad at low load is unevenly wetted: some of the mesh is running with a film, some of it is damp rather than irrigated. Salts and polymers crystallise or cure in the damp zones, and the deposit does not show up until the plant returns to full rate and the pad floods locally against its own fouling. By then the evidence points at the pad, while the cause was a long period at low load.
What the pressure drop reading does not tell you
Pressure drop across a clean element is close to proportional to gas density times velocity squared, so it is also proportional to flow squared. A reading taken at 50 per cent flow should be about a quarter of the design value; a reading at 25 per cent flow should be about a sixteenth. If the reading stays high while the flow falls, the element is fouled; if the reading falls faster than the square law predicts, the gas is bypassing the element or the flow measurement is wrong.
The usable diagnostic is therefore not the absolute DP but the ratio of DP to flow squared, tracked over time. A ratio that creeps upward is fouling that has not yet produced an alarm. A ratio that steps downward is a mechanical change: a collapsed pad section, a displaced vane block, a hole in the element, or a liquid seal that has been lost so that the element is no longer being irrigated.
Where the failure really starts: upstream distribution
Most carryover at low load is not an eliminator problem at all. It is the distribution upstream of it, and the eliminator is simply the place where the consequence becomes visible.
At design flow, a perforated distributor or a calming baffle develops a pressure drop across its holes large enough to force every hole to flow. At low flow that drop falls with the square of velocity, and below a threshold the gas stops sealing the holes: some holes flow, some stop, and liquid standing on the plate drains through the inactive ones. The plate has changed from a distributor into a sieve. Downstream, the gas arrives at the eliminator in sectors, with one part of the cross-section at twice the average velocity and another part at almost nothing.
The eliminator then does exactly what its curve says. The fast sector is locally above its flooding velocity and re-entrains; the slow sector is below its capture velocity and passes fine mist. Both failures appear at the same time, which is why the report reads as contradictory: carryover with droplets that are too large and too small in the same sample.
The same pattern appears in trays and downcomers, where the liquid seal is lost at low vapour rate and vapour bypasses the tray, and in cyclones, where the swirl weakens until the liquid film on the wall breaks into rivulets and leaves dry patches that scale or corrode. In every case the device is being asked to work outside the range in which its geometry was defined, and the fix belongs upstream or in the specification, not in the element.
Worked example: one unit at three flows
Take a duty of 1.2 m3/s of gas at 1.2 kg/m3 with liquid at 1000 kg/m3, and size two elements against the same maximum velocity expression, u = K times the square root of (liquid density minus gas density) divided by gas density. Use K of 0.107 m/s for knitted mesh and 0.152 m/s for a vertical vane pack, and design both at 70 per cent of the resulting maximum.
Mesh: maximum velocity 3.09 m/s, design velocity 2.16 m/s, required area 0.556 m2, diameter 0.84 m. Vane: maximum 4.39 m/s, design 3.07 m/s, area 0.391 m2, diameter 0.71 m. Now hold the geometry and reduce the flow.
| Quantity | 100 per cent, 1.2 m3/s | 50 per cent, 0.6 m3/s | 25 per cent, 0.3 m3/s |
|---|---|---|---|
| Mesh velocity through 0.84 m pad | 2.16 m/s | 1.08 m/s | 0.54 m/s |
| Vane velocity through 0.71 m pack | 3.07 m/s | 1.53 m/s | 0.77 m/s |
| Vane cut size, approximate | 10 micron | 14 micron | 20 micron |
| Mesh cut size, approximate | 4 micron | 6 micron | 8 micron |
| Mesh pressure drop | 60 Pa | 15 Pa | 4 Pa |
| Vane pressure drop | 100 Pa | 25 Pa | 6 Pa |
The cut sizes are scaled on constant Stokes number, which is an approximation and not a guarantee; they are there to show the direction and the size of the effect, not to replace a vendor curve. The conclusion is visible anyway: at quarter flow the vane pack is effectively a gutter, while the mesh still holds droplets near 8 microns. The two curves cross somewhere near half flow, which is why a two-stage arrangement works across a wide range – not because two stages are inherently better, but because the second stage covers the end of the range the first stage cannot.
What to write into the datasheet to survive turndown
- Give the flow range, not the design point: minimum, normal and maximum, each with its own gas density. A separator sized against one number will be judged against a curve.
- State the efficiency required at each of those points, not only at maximum. The data that matters is the droplet size that must be held at minimum flow.
- State the liquid load range separately. Liquid turndown is usually wider than gas turndown and is often the case that actually breaks the element.
- Require the vendor’s efficiency curve and the velocity at which it was computed, so the cut size at your minimum can be read off rather than assumed.
- Specify the minimum acceptable gas velocity in the element, and the maximum. The two limits belong in the same table, because a device can pass one and fail the other.
- For any perforated distributor upstream, specify the minimum hole pressure drop at turndown, so the plate keeps sealing instead of weeping.
- Write the start-up condition, including the pre-fill of the liquid seal, into the same document. A dry seal at low load re-entrains whatever the element captures.
None of these lines costs anything at the quotation stage. They cost a rewrite if they are missing, because by then the element has been bought against a single point and the plant has to live with the curve on either side of it.
Reference
Velocity limits and the K value convention used here are the ones applied in the other notes on this site; the two-stage argument is worked through in the selection map, and the seal and pre-fill requirements are set out in the note on separator problems that start outside the vessel.
Frequently Asked Questions
At what percentage of design flow does a vane pack stop working?
There is no single number, because it depends on the cut size the duty needs. A pack that must hold 10 microns is visibly degraded by 50 per cent flow; a pack that only has to hold 40 microns may be acceptable to 30 per cent. The reliable statement is the one you can compute: cut size scales roughly as one over the square root of velocity.
Is a mesh pad better than a vane pack at low flow?
For capture of fine mist, yes, because interception and diffusion keep working after impaction falls away. For capacity and for heavily loaded duties at high flow, no. That is why the two are often combined rather than chosen between.
Why does carryover appear only at low load?
Usually because the distribution upstream collapses before the element does. A perforated plate that seals at design flow weeps at low flow, the gas arrives in sectors, and part of the element is above its flooding velocity while another part is below its capture velocity. Check the distributor pressure drop and the deposit pattern on the element before changing the element.
Does low flow mean lower pressure drop?
Yes, close to the square of the flow ratio. That is exactly why a low reading at low load tells you nothing about fouling. Track DP divided by flow squared instead; the ratio stays constant for a clean element and rises as it fouls.
Should the separator be designed for minimum flow?
Size the cross-section against maximum flow with a flooding margin, then verify capture at minimum flow. If the required window is wider than one device can hold, use two stages with different curves rather than pushing one device outside its range.
Related notes: the selection map by duty, problems that start outside the vessel, why the same duty gives different diameters.
- Gas-Liquid Separation Fundamentals — terminology, separation mechanisms and internal selection
- Technical Data Sheet — material and performance reference data
- All Technical Articles — complete engineering index
If you are working on a replacement
A wire mesh pad performs only if it seals to the shell all round, so the measured inside diameter matters as much as the mesh density. See the process data needed to size and select it, what can and cannot be compressed on an urgent replacement and the scope from data review through to delivery.
More on wire mesh demisters and demister pads
- How Does a Wire Mesh Demister Work? A Complete Guide – the guide that covers this device family end to end
- Demister Sizing: Why Western and Chinese Conventions Give Different Diameters
- Reboiler Mist Eliminators in Ethylene, C3 Splitter Heat Pumps and Refrigeration Chillers
- Why a Shorter Kettle Bundle Can Need a Larger Shell: Length, Diameter and Which Area Binds
- Entrainment Prediction in Kettle Reboilers, Why the Element Is Not Free to Size, and What CFD Is Actually For